48V/51.2V wall-mounted LiFePO4 battery,6000 cycles
Light weight, Small size/501*452*155mm
Support a variety of communication protocols, support RS485, RS232, CAN etc
Intelligent battery management system,Compatible with a variety of inverters。

Nvanc 5KWh Solar PowerWall 48V 100Ah Home Wall Mounted Lithium Ion Battery Storage Battery Specifications

Model No

A-5kWh

Nominal Parameters

Voltage

48V

Capacity

100Ah

Energy

4.8kWh

Dimensions (L x W x H)

501 x452 x155mm

Weight

48kg

Basic Parameters

Life time(25°C)

10 years

Life cycles(80% DOD, 25°C)

6000Cycles

Storage time / temperature

5 months @ 25°C; 3 months @ 35°C; 1 month @ 45°C

Operation temperature

-20°C to 60°C @60+/-25% Relative Humidity

Storage temperature

0°C to 45°C @60+/-25% Relative Humidity

Lithium Battery Standard

IEC62619,UN38.3,ROHS,CE-EMC

Enclosure protection rating

IP21

Electrical Parameters

Operation voltage

40.5 Vdc

Max. charging voltage

54.7 Vdc

Max. charging and discharging current

100A

Max Power

4800W

Details

Standard

Overcharge detection voltage

3.65±0.025V

Overcharge detection delay time

Typical:1.0s

Overcharge release voltage

3.38±0.02V

Over-discharge detection voltage

2.5±0.02V

Over-discharge detection delay time

Typical:1.0s

Over-discharge release voltage

2.9±0.02V or charge release

discharge Over-current protection current1

130±10A

discharge Over-current detection delay time 1

1S

discharge Over-current protection current 2

150±10A

discharge Over-current detection delay time 2

≤100m±50ms

Charge OC protection current

130±10A

Short protection current

350±10A

Protection condition

Load short

Detection delay time

≤300us

Protection release condition

Charging release

Charge high T protection

55±3℃

Charge high T recover

50±5℃

Discharge high T protection

65±5℃

Discharge high T recover

60±5℃

Charge low T protection

-5±5℃

Charge low T recover

0±5℃

Discharge low T protection

-20±5℃

Discharge low T recover

-15±5℃

Balance threshold voltage

3.45V

 Communication

It has RS232 /RS485 and Canbus standard communication interface, it can real-time monitoring the capacity of battery bank, the voltage, current, environment temperature, and charging/discharging current.

 Alarm

 It has over-temperature, over charge, under-voltage, over-current, short circuit alarm Function.